499,000 BTU/146 kW per hour The EL-500B Waste Oil Boiler Commonly Used Fuels: Used crankcase oils, ATF, hydraulic fluid, No. 2 fuel oil, and diesel fuel.

EL-500B Specifications Parts List
SPECIFICATIONS:
Commonly Used Fuels Used crankcase oils, ATF, hydraulic fluid, No. 2 fuel oil, and diesel fuel Fuel Meter Pump Precision metering over a wide range of fuels UL Certification UL listed system
Fuel Flow Rate 3.6 gallons/13.6 liters per hour BTU Input 499,000 BTU/146 kW per hour Water Output Temp. (max) 230 F /110 C Domestic Hot Water Output 8.0 gallons / 30 liters per minute at 100 F / 37.8 C temp rise Heat Exchanger Wet floor based design Boiler Capacity 52 gallons / 196.84 liters System Dimensions 45"H x 32"W x 68"D / 114cm H x 82cm W x 173cm L Hour Meter Analog (Clocks only actual burn time, not blower) Exhaust Flue Diameter 10" / 25.4cm diameter Fuel Tank Single wall 250 gal./946.35 liter workbench. Double wall workbench available Electrical Req. 115 VAC 60Hz, 20 amps dedicated curcuit Shipping Weight System with tank - 1550lbs. / 703kg System without tank - 1125lbs. / 510kg Standard Features Integrated Air Compressor Barometric Damper, Draft Gauge Optional Features Various Size Fuel Tanks
|